40m3/Hr VFD Control Start Helium Gas Cylinder Filling Compressor

Product Details
Customization: Available
Lubrication Style: Oil-free
Cooling System: Water Cooling
Still deciding? Get samples of US$ 18888/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
443406.54 USD
Terms of Payment
LC, T/T, PayPal, Western Union
OEM/ODM Availability
Yes
  • 40m3/Hr VFD Control Start Helium Gas Cylinder Filling Compressor
  • 40m3/Hr VFD Control Start Helium Gas Cylinder Filling Compressor
  • 40m3/Hr VFD Control Start Helium Gas Cylinder Filling Compressor
  • 40m3/Hr VFD Control Start Helium Gas Cylinder Filling Compressor
  • 40m3/Hr VFD Control Start Helium Gas Cylinder Filling Compressor
  • 40m3/Hr VFD Control Start Helium Gas Cylinder Filling Compressor
Find Similar Products

Basic Info.

Model NO.
GV-40/1.5-8
Cylinder Arrangement
Balanced Opposed Arrangement
Cylinder Position
Vertical
Structure Type
Closed Type
Compress Level
Single-Stage
Refrigerant Type
According to Client′s Requirement
Product Name
High Pressure Oxygen Compressor
Model
Gv-40/1.5-8
Compressed Medium
99.9%+ H2 O2 He Gas Air
Flow Rate
2nm3/H
Power (Kw)
4kw
Inlet Pressure ( MPa)
0.01MPa(G)
Exhuast Pressure (MPa)
12.0MPa(G)
Cooling Method
Water Cooling Customized
Speed
420r/Min
Drive Mode
Belt Driven
Advantage 1
Contamination Free;Compression
Advantage 2
100% Purity No Leakage Design, Suitable for Medica
Advantage 3
Automatic Shutdown for Diaphragm Failure
Advantage 4
High Compression Ratios-Discharge Pressure 700bar
Application
Vacuum Systems for Evaporation
Transport Package
Wooden Package, by Sea
Specification
1550*900*1050mm
Trademark
700kgs
Origin
China
HS Code
84148090
Production Capacity
200sets/Month

Product Description

40m3/Hr VFD Control Start Helium Gas Cylinder Filling Compressor
Diaphragm Compressor 100% purity no leakage Oil-free Helium Gas Booster Compressor 

The diaphragm compressor booster is a special structure of the volume-type compressor with high compression ratio, good leak tightness, compressed gas without lubricating oil and other solid impurities contaminated features, So it's suitable for high purity compression, rare, valuable, inflammable, explosive, toxic, harmful, corrosive, and high pressure gas

Advantages of Diaphragm compressor:
1.  Oil-free compression due to the hermetic separation between gas and oil chamber.
2.  Abrasion-free compression due to static seals in the gas stream
3.  Automatic shutdown in case of a diaphragm failure prevents damage
4.  High Compression Ratios-Discharge pressure up to 1000bar.
5.  Contamination Free Compression
6.  Corrosion Resistance
7.  High Reliability

As a displacement compressor with special,diaphragm compressor is characterized by large compression ratio,good sealing performace,and that the compress air will not be polluted by lubricant or other solid impurities.Therefore diaphragm compressor is applicable to compress high-purity,rare and precious,flammable and explosive,toxic and hazardous,corrosive and high pressure gases.
Keepwin diaphragm compressors consist of four types that are Z,V,L and D type.The exhaust pressure ranges from 1.3 to 100 Mpa. The products are widely used in the industries of national defense,scientific research,petrochemical,nuclear power,parmaceutical,food-stuff and gas separation.


Helium compressors are widely used in Petrochemicals, Fine Chemicals, Pharmaceutical Chemicals, Energy Chemicals, Machinery Industry, Electronics Industry, Agriculture, Animal Husbandry and Defense Industry.
It is mainly used in Vacuum Systems for Evaporation, Sputtering and Ion Implantation of Semiconductor front-end process equipment, and also has a wide range of applications in Astronomy, Aerospace, Medical and other fields. 

40m3/Hr VFD Control Start Helium Gas Cylinder Filling Compressor40m3/Hr VFD Control Start Helium Gas Cylinder Filling Compressor
Inquiry to us!
Note:for the other customizing process gas compressor, please kindly send below information to our factory to calculate the producing cost for your item.
Clients' inquiries should contain related parameters 
A. The gas compression medium 
B. Gas composition? or the gas purity?
C. The flow rate: _____Nm3/hr
D. Inlet pressure: _____ Bar (gauge pressure or absolute pressure)
E. Discharge pressure: _____ Bar (gauge pressure or absolute pressure)
F. Inlet temperature
G.Discharge temperature
H. Cooling water temperature as well as other technical requirement.


Technical Paramter of Oil Free Diaphragm Compressor
GZ type Diaphragm Compressor Technical Parameters
No. Model F.A.D (Nm3/min) Inlet Pressure 
( Mpa)
Exhuast Pressure 
(Mpa)
Power 
(KW)
Speed
r/min
Dimension
(L×W×H)mm
N.W 
Weight (t)  
Voltage
V
1 G2V-10/8-160 10 0.8 16 5.5 400 1550*900*1050 0.8 380
2 G2V-5/3.5~150 5 0.35 15 5.5 400 1550*900*1050 0.8 380
3 G2V-10/4~320 10 0.4 32 5.5 430 1650*850*1250 0.8 380
4 G3V-240/5~12 240 0.5 1.2 18.5 400 1860*1200*1585 2 380
5 G3V-1200/75~83 1200 7.5 8.3 18.5 400 1780*1050*1750 1.8 380
6 G3V-80/13~150 80 1~1.5 15 22 330 2400*1350*1465 2.1 380
7 G3V-30/5~315 30 0.5 31.5 15 400 2010*955*1455 1.8 380
8 G3V-80/7~150 80 0.7 15 22 400 2302*1385*1444 2.5 380
9 G2V-25/6~150 25 0.6 15 7.5 400 1500*775*1075 0.8 380
10 G2.5V-10/160 10 Normal 16 7.5 400 1650*1020*1400 0.95 380
11 G2.5V-20/1~160 20 0.1 16 11 400 1650*1020*1400 0.95 380
12 G2.5V-16/2.5~160 16 0.25 16 7.5 400 1650*1020*1400 0.95 380
13 G3V-100/24~125 100 2.4 12.5 22 400 2160*1250*1500 1.8 380
14 G4V-220/99-349 220 7.0~25 34.9 37 400 2492*1840*1610 3.2 380
15 G2Z-45/150~350 45 10~20 35 7.5 400 1610*790*1380 0.55 380
16 G2Z-5/30~400 5 3 40 5.5 400 1560*790*1470 0.55 380
17 G2.5Z-30/32~170 30 3.2 17 7.5 400 1550*650*1530 0.7 380
18 G3Z-600/75~83 600 7.5 8.3 11 400 1780*1050*1750 1.3 380
19 G3Z-85/100~350 85 5~25 35 18.5 400 1900*1240*1760 1.6 380
20 G3Z-150/150~350 150 15 35 18.5 400 1780*1050*1750 1.8 380
21 G2.5Z-40/7~30 40 0.7 3 7.5 400 1653*1372*1470 0.9 380
22 G2.5Z-100/20~35 100 2 3.5 5.5 400 1330*750*1530 0.9 380
23 GV3-110/8~150 110 0.8 15 30 400 2370*1458*1630 3 380
24 G3V-150/3.5~30 150 0.35~0.55 3 30 400 2543*1835*2036 3.21 380
25 G3V-60/0.38~9.3 60 0.038 0.93 15 400 2030*1520*1750 72 380

40m3/Hr VFD Control Start Helium Gas Cylinder Filling Compressor
40m3/Hr VFD Control Start Helium Gas Cylinder Filling Compressor

Main technical data

Cylinder 
All the cylinders comprise upper plate, diaphragms, and cylinder body etc. The diaphragms are clamped between the cylinder cover and cylinder body. The cylinder cover and cylinder body each has a concave recess hollowed out in their contacting faces. The gas cylinder is formed between cylinder cover concave recess and diaphragms. Both suction valve and discharge valve are fitted on the upper plate. Among of them, the discharge valve is located on the center of the upper plate. The evenly located small oil holes are on the cylinder body to deliver the oil pressure inside the oil cylinder to the bottom of diaphragms (each diaphragm compressor's cylinder has three piece diaphragm.) 

Pressure Regulating Valve 
The oil pressure of oil cylinder is regulated by the tension of the valve spring.In case the oil pressure is higher than the regulated value, turn the regulating bolt counter-clockwise to loosen the spring tension, but turn the regulating bolt clockwise to tighten the spring, when the oil pressure is lower than the regulated value. When the oil pressure meets the required value, the regulating bolt must be locked with a lock-nut. The oil pressure of the oil cylinder shall always be higher than the discharge pressure by 15~20%. But the oil and gas differential pressure shall not be lower than 0.3MPa or higher than 1.5MPa. 

Cooler
The cooler structure is the double-wall pipe type. The circular space between the outer and inner pipe is the cooling water passage and the inner pipe is the gas passage. Normally the water inlet port is at the lower side and the water outlet port is at the upper side. The flow direction of cooling water and gas is on the contrary.
40m3/Hr VFD Control Start Helium Gas Cylinder Filling Compressor

Oil Pressure Measuring Device 
The measuring device of oil cylinder discharge pressure consists of shock-proof pressure gauge, check valve and unloading valve. The case of the pressure gauge is totally airproof and filled with damping liquid. The inner devices of gauge is immersed in the liquid, which makes the pressure gauge hands stable through the function of the viscosity of damping liquid. The unloading valve is fitted under the gauge to discharge the remained air in the oil pipeline and to unload the oil pressure gauge. Also the check valve connecting with oil cylinder through pipeline is fitted under the unloading valve.   

Oil pipes 
Oil pipes consist of lube oil pipe and oil pressure secure system.
The lubrication for the driving device adopts gear oil pump circulation pressure lubricating. The lube oil stored in the frame oil tank enters into the gear oil pump after being filtered and is pressed into the oil holes in the crankshaft through the gear oil pump to lubricate the crankshaft friction surface. At the same time, part of the lube oil reaches the crosshead pin and crosshead along the oil holes in the connecting rod to lubricate the friction surface. The oil pressure of gear oil pump shall be kept between 0.3~0.5Mpa, and the bearings at the two ends of crankshaft is splash lubricated. 
Oil pressure secure system consists of oil compensating pipe, pressure-measuring pipe and oil return pipe. The oil output from the oil compensating pump will supplement oil for compressor cylinders through the oil compensating pipe and the excess oil returns to the crankcase through the pressure-regulating valve.

40m3/Hr VFD Control Start Helium Gas Cylinder Filling Compressor
40m3/Hr VFD Control Start Helium Gas Cylinder Filling Compressor


FAQ
Q1: What's your delivery time?
A: Generally 5-10 days if the goods are in stock. Or it is 20-35 days if the goods are not in stock, it is according to quantity.

Q2: How long is your air compressor warranty?
A: Usually 1 year /12 Months for whole compressor machine, 2years/24months for air end (except maintenance spare parts.). And we can provide further warranty if necessary. 

Q3: How long could your air compressor be used?
A: Generally, more than 10 years.

Q4: Can you do OEM for us?
A: Yes, of course. We have around two decades OEM experience.And also we can do ODM for you.

Q5: What's payment term?
A: T/T, L/C, D/P, Western Union, Paypal, Credit Card, Trade Assurance and etc. Also we could accept USD, RMB, GBP, Euro and other currency.

Q6: How about your customer service?
A: 24 hours on-line service available. 48hours problem sovled promise.

Q7: How about your after-sales service?
A: 1. Provide customers with intallation and commissioning online instructions.
2. Well-trained engineers available to overseas after-sales service. 

Q8. Are you factory?
A4: Absolutely! You have touched the primary sources of Air /Gas Compressor. We are factory.

How to contact with us?
Send your Inquiry Details in the Below, or Click "Send inquiry to supplier" to check more other Gas Compressor machine equipment!
40m3/Hr VFD Control Start Helium Gas Cylinder Filling Compressor
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier